DAA Primafill


  • Semiautomatisk tennhettefyller
  • Passer small og large primer
  • Batteri/tennhetterør følger ikke med

Kr. 975 ,-

Ikke på lager - Kan restbestilles

Produktnummer: DAA103288 Kategorier: , , Merke:

Om man syns Primer-Pro blir for kostbar eller bruker både small og large primer så kan PRIMAFILL være løsningen for deg.
En semiautomatisk tennhettefyller.
Den lar deg enkelt og kjapt fylle opp tennhetterørene.
Samme maskin fungerer både til large og small primer!

Se video for hvordan produktet virker.

Vanlig 8mm primer rør passer (følger ikke med) og kan kjøpes ved siden. DAA sine nye primer tubes er en ypperlig kombo.
Bruker 9v batteri (følger ikke med)

Operating Instructions:

  1. Ensure a 9v battery is inserted and test by pushing the powder button. The device should vibrate and hum gently in  your hand. Do not remove the foam pad from under the battery, it is required there.
  2. Remove the lid, and position the magnetically-retained stopper to block either the LARGE or the SMALL exit hole to match your needs. Flip it over when moving it from one side to the other.
  3. Stand the PRIMAFILL on a flat table, and place 100 primers on the flip tray area.
  4. With the device resting on a smooth table top, slide it around with short, sharp motions to flip all the primers until they are all anvil side  up.
  5. Replace the lid and insert a primer tube into the appropriate exit hole. Push down on the orange latch as you insert the pipe into place, and make sure it seats all the way home.
  6. Hold the device in  you right hand, with  your index finger on the button and your thumb centered on the lid. Tilt the PRIMAFILL so that the primers bunch-up near the BLOCKED exit hole (so by the LARGE when feeding SMALL primers)
  7. Activate the vibratory motor by pressing and holding the power button, then gradually tilt the device towards the open exit hole (to the right for SMALL primers) so that a single (or at most a double) row is formed towards the exit hole. Also tilt the device towards you to assist the primers in running down the exit channel to the exit hole. Do not tilt more than necessary in either axis. Try to keep the PRIMAFILL as horizontal as possible, while still creating sufficient motion in the primers.

Please Note:

  • Various brands of primers will flip best with different types of agitation motion of the flip tray. Experiment to find the optimal flip tray action required to flip your primers.
  • Various types of primers will slide differently, at different speeds. Some will require you to hold the device at a steeper angle to get them moving properly. Experiment a little to find the correct feeding angle best for your primers.
  • If a primer hangs on the exit hole, a tap with your left hand finger on top of the lid above the hole should clear that up instantly. No need to stop the vibration of the device or remove the lid.
  • If your primer tubes have an entry hole chamfer that is not well formed or not symmetrical, this can create a ledge that primers may hang up as they fall down into the tube. Try using the other end of your tube. Or, try rotating the tube to find the angle that allows the primers to flow uninterruptedly into the tube. You can mark that with a Sharpie on  your tube, so  you can easily position it again the same way.
  • Primer Tubes are NOT included with the device, in order to reduce costs and packaging size. Order tubes separately, if you need them.
Dette nettstedet bruker informasjonskapsler (cookies) for å tilpasse innholdet, skreddersy din opplevelse og holde deg innlogget dersom du registrerer deg. Ved å fortsette og bruke dette nettstedet, samtykker du i bruken av informasjonskapsler.